Technical Specifications

 

Performance

Supply

Conditions

Min.

Typ.

Max.

Units

Supply power

Via one connected I/O module

4.75

5

5.25

Vdc

Power consumption

 

-

0.4

0.8

W

 

General

Conditions

Min.

Typ.

Max.

Units

Controlled by 6172

see CAN Core Module 6172

-

-

- -

Warranty

-

-

2

-

year

 

CAN-bus

Conditions

Min.

Typ.

Max.

Units

Bit rate timing table

Selectable

10

-

1000

kbit

Protocol

CAN V 2.0a

- - - -

Application layer CANopen

Field upgradable

- - - -
 

Connectors

Type

CAN bus connector

9 pole sub-D male

Cdios bus

10 pole flatcable male

 

Signaling LEDs

Color

Text

CAN communication

Red

Node active

Red

Bus active

 

Environmental

Conditions

Min.

Typ.

Max.

Units

Operating temperature

-

-20

-

70

°C

Storage temperature

-

-25

-

80

°C

Relative humidity

at 40°C non Cond.

-

-

90

%

Burn in cycle

25°C .. -25°C .. 60°C

-

1

-

cycle

 

Physical

Housing

35 mm DIN rail

Dimensions L * W * H

96 * 61 * 55 mm (incl. rail)

Color

Light Grey

Protection class

IP32

Weight

105 g

 

Conformity

EN 50081-1

Electromagnetic compatibility -Generic emission standard- Residential, commercial and light industry environment

EN 50081-2

Electromagnetic compatibility -Generic emission standard- Industrial environment

EN 50082-1

Electromagnetic compatibility -Generic immunity standard-Residential, commercial and light industry environment

EN 50082-2

Electromagnetic compatibility -Generic immunity standard- Industrial environment

EN 55022

Emits and methods of measurement of radio disturbance characteristics of information technology equipment

EN 61010-1

Safety requirements for electrical equipment for measurement, control and laboratory use