Stepper Motor Controller
Cdios 6166

Technical Specifications

 

Supply

Conditions

Min. Typ. Max. Units
Supply power Serial no < 121xxxxx 23 24

25

Vdc
  12 - 28
Power consumption Serial no < 121xxxxx - 2 3

W

    1.8 2
Power on Current During power on - 235 - mA
Fuse slow   - 8 - A
 

Stepper motor

Conditions

Min. Typ. Max. Units
Coils Isolated to Cdios - 2 - pcs
Step frequency Half stepping 62   30.000 Hz
Coil current Software adjustable 0 - 4 A
Standby Coil current Software adjustable 0 - 4 A
 

Input

Conditions

Min. Typ. Max. Units
No. Inputs Isolated to Controller - 3 - pcs
Voltage Serial no <121xxxxx 8 24 30 Vdc
See power supply 12 - 36
Switch threshold - 5 - 9.5 Vdc
Impedance - -

4.4

- kOhm
 

Connectors

Type

Power supply 2 pole screw/plug connector
Motor 4 pole screw/plug connector
Input 1-3 6 pole screw/plug connector
Cdios bus 10 pole Flatcable female
10 pole Flatcable male
 
Signaling LEDs Color Text
On each input Red Active
 

General

Conditions

Min. Typ. Max. Units
I/O module Controlled by Cdios controller

-

- - -
Module select via 4 dipswitches - - - -
MPU Motorola 68HC908 - 8 - Mc
MPU watchdog - - 52 - ms
MTBF T amb..=40°C - 87000 - h
Warranty - - 2 - year
 

Environmental

Conditions

Min. Typ. Max. Units
Operating temperature - -20 - 70 °C
Storage temperature - -25 - 80 °C
Relative humidity at 40°C non Cond. - - 90 %
Burn in cycle 25°C .. -25°C .. 60°C - 1 - cycle
 

Physical

Housing 35 mm DIN rail
Dimensions L * W * H 96 * 61 * 55 mm (incl. rail)
Color Light Grey
Protection class IP32
Weight 268 g
 

Conformity

EN 50081-1 Electromagnetic compatibility -Generic emission standard- Residential, commercial and light industry environment
EN 50081-2 Electromagnetic compatibility -Generic emission standard- Industrial environment
EN 50082-1 Electromagnetic compatibility -Generic immunity standard-Residential, commercial and light industry environment
EN 50082-2 Electromagnetic compatibility -Generic immunity standard- Industrial environment
EN 55022 Emits and methods of measurement of radio disturbance characteristics of information technology equipment
EN 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use

 


Home