Analog Servo Motor Controller / Driver
Cdios 6167

Technical Specifications

 

Supply

Conditions

Min. Typ. Max. Units
Supply power Serial no < 121xxxxx 23 24

25

Vdc
  12 - 28
Power consumption Motor not running 1.5 2.5 4 W
Power on Current During power on - 300 - mA
Fuse slow - -

2.5

- A
 

DC motor

Conditions

Min. Typ. Max. Units
Output voltage Isolated to Cdios~ Supply -
4
Supply -
2.5
Supply -
1.5
Vdc
Output current - - 2 A
Offset Voltage Motor off, Supply voltage 12-28V -0.1 - 0.1 V
Motor Current Measurement Error Motor voltage 24V - - 80 mA
 

Encoder

Conditions

Min. Typ. Max. Units
Differential input voltage A, /A, B, /B, I, /I inputs -200 35 200 mV
Common mode range -10 - 10 Vdc
Input resistance 5 6.8 10 kOhm
Max. Input frequency
(*4 is amount of positions)
- - 200 kHz
Z-Input setup time Z-before Index pulse active in AutoZero mode and Z+I homing 50 - - µS
 

Input

Conditions

Min. Typ. Max. Units
No. Inputs Isolated to Controller

Fwd, Rev, Emg and Z

- 4 - pcs
Voltage - 0 - 30 Vdc
Switch threshold - 4 - 11 Vdc
Impedance - -

4.4

- kOhm
 

Connectors

Type

Power supply 3 pole screw/plug connector, separate Logic and power connection
Motor 2 pole screw/plug connector
Fwr, Rev, Emg, Z 6 pole screw/plug connector
Encoder 8 pole screw/plug connector
Cdios bus 10 pole Flatcable female
10 pole Flatcable male
 
Signaling LEDs Color Text
On each input Red Active
 

General

Conditions

Min. Typ. Max. Units
I/O module Controlled by Cdios controller

-

- - -
Module select via 4 dipswitches - - - -
MPU Motorola 68HC908 - 8 - Mc
MPU watchdog - - 52 - ms
MTBF T amb..=40°C - 87000 - h
Warranty - - 2 - year
 

Environmental

Conditions

Min. Typ. Max. Units
Operating temperature - -20 - 70 °C
Storage temperature - -25 - 80 °C
Relative humidity at 40°C non Cond. - - 90 %
Burn in cycle 25°C .. -25°C .. 60°C - 1 - cycle
 

Physical

Housing 35 mm DIN rail
Dimensions L * W * H 96 * 61 * 55 mm (incl. rail)
Color Light Grey
Protection class IP32
Weight 101 g
 

Conformity

EN 50081-1 Electromagnetic compatibility -Generic emission standard- Residential, commercial and light industry environment
EN 50081-2 Electromagnetic compatibility -Generic emission standard- Industrial environment
EN 50082-1 Electromagnetic compatibility -Generic immunity standard-Residential, commercial and light industry environment
EN 50082-2 Electromagnetic compatibility -Generic immunity standard- Industrial environment
EN 55022 Emits and methods of measurement of radio disturbance characteristics of information technology equipment
EN 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use

 


Home