Analog Servo Motor
Controller / Driver
|
|
Supply |
Conditions |
Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| Supply power | Serial no < 121xxxxx | 23 | 24 |
25 |
Vdc |
| 12 | - | 28 | |||
| Power consumption | Motor not running | 1.5 | 2.5 | 4 | W |
| Power on Current | During power on | - | 300 | - | mA |
| Fuse slow | - | - |
2.5 |
- | A |
|
DC motor |
Conditions |
Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| Output voltage | Isolated to Cdios~ | Supply - 4 |
Supply - 2.5 |
Supply - 1.5 |
Vdc |
| Output current | - | - | 2 | A | |
| Offset Voltage | Motor off, Supply voltage 12-28V | -0.1 | - | 0.1 | V |
| Motor Current Measurement Error | Motor voltage 24V | - | - | 80 | mA |
|
Encoder |
Conditions |
Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| Differential input voltage | A, /A, B, /B, I, /I inputs | -200 | 35 | 200 | mV |
| Common mode range | -10 | - | 10 | Vdc | |
| Input resistance | 5 | 6.8 | 10 | kOhm | |
| Max. Input frequency (*4 is amount of positions) |
- | - | 200 | kHz | |
| Z-Input setup time | Z-before Index pulse active in AutoZero mode and Z+I homing | 50 | - | - | µS |
|
Input |
Conditions |
Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| No. Inputs |
Isolated to Controller
Fwd, Rev, Emg and Z |
- | 4 | - | pcs |
| Voltage | - | 0 | - | 30 | Vdc |
| Switch threshold | - | 4 | - | 11 | Vdc |
| Impedance | - | - |
4.4 |
- | kOhm |
|
Connectors |
Type |
|---|---|
| Power supply | 3 pole screw/plug connector, separate Logic and power connection |
| Motor | 2 pole screw/plug connector |
| Fwr, Rev, Emg, Z | 6 pole screw/plug connector |
| Encoder | 8 pole screw/plug connector |
| Cdios bus | 10 pole Flatcable female |
| 10 pole Flatcable male |
| Signaling LEDs | Color | Text |
| On each input | Red | Active |
|
General |
Conditions |
Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| I/O module | Controlled by Cdios controller |
- |
- | - | - |
| Module select | via 4 dipswitches | - | - | - | - |
| MPU | Motorola 68HC908 | - | 8 | - | Mc |
| MPU watchdog | - | - | 52 | - | ms |
| MTBF | T amb..=40°C | - | 87000 | - | h |
| Warranty | - | - | 2 | - | year |
|
Environmental |
Conditions |
Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| Operating temperature | - | -20 | - | 70 | °C |
| Storage temperature | - | -25 | - | 80 | °C |
| Relative humidity | at 40°C non Cond. | - | - | 90 | % |
| Burn in cycle | 25°C .. -25°C .. 60°C | - | 1 | - | cycle |
|
Physical |
|
|---|---|
| Housing | 35 mm DIN rail |
| Dimensions L * W * H | 96 * 61 * 55 mm (incl. rail) |
| Color | Light Grey |
| Protection class | IP32 |
| Weight | 101 g |
|
Conformity |
|
|---|---|
| EN 50081-1 | Electromagnetic compatibility -Generic emission standard- Residential, commercial and light industry environment |
| EN 50081-2 | Electromagnetic compatibility -Generic emission standard- Industrial environment |
| EN 50082-1 | Electromagnetic compatibility -Generic immunity standard-Residential, commercial and light industry environment |
| EN 50082-2 | Electromagnetic compatibility -Generic immunity standard- Industrial environment |
| EN 55022 | Emits and methods of measurement of radio disturbance characteristics of information technology equipment |
| EN 61010-1 | Safety requirements for electrical equipment for measurement, control and laboratory use |
| Home | Last Modified: 1 February 2006 |