Four  1Volt / 100mV Input Module
Cdios 6170

Technical Specifications

 

Supply

Conditions

Min. Typ. Max. Units
Supply power  
12 - 28 Vdc
Power consumption  
- 0.8 1.3 W
Power on Current During power on - 110 - mA
Fuse slow auto reset - 0.2 - A
 

Ground terminal

Conditions

Min. Typ. Max. Units
Voltage with respect to 
supply ground

 

Volt or 100mV input at positive 
voltage with respect to ground

-0.15 0 +0.85 Vdc

Volt or 100mV input at negative 
voltage with respect to ground

-0.05 0 +1.05 Vdc
 

 1V Input

Conditions

Min. Typ. Max. Units
No. Inputs Isolated to bus - 4 - pcs
Range - -1 - +1 Vdc
Resolution basic sample rate 50/60 
samples per second
- 0.03 - mV
Accuracy Ambient temperature 25°C - 0.01 - % FS
Non-linearity - - - 0.01 % FS
Impedance - - 50 - K Ohm
Over voltage protection - - 60 - Vdc
Line rejection 50/60 Hz 80 - 100 dB
Temperature drift - - 10 - ppm/°C
 

 100mV Input

Conditions

Min. Typ. Max. Units
No. Inputs Isolated to bus - 4 - pcs
Range - -100 - +100 mV
Resolution basic sample rate 50/60 
samples per second
- 0.003 - mV
Accuracy Ambient temperature 25°C - 0.01 - % FS
Non-linearity - - - 0.01 % FS
Impedance - - 10 - K Ohm
Line rejection 50/60 Hz 80 - 100 dB
Temperature drift - -

10

- ppm/°C
 

 Sample interval times / resolution

 

       
Basic sample rate (samples per second) 1 input 2 inputs 3 inputs 4 inputs effective resolution
200 5 mS 10 mS 15 mS 20 mS 0.048% (11 bits + sign)
100 10 mS 20 mS 30 mS 40 mS 0.012% (13 bits + sign)
60 17 mS 33 mS 50 mS 67 mS 0.003% (15 bits + sign)
50 20 mS 40 mS 60 mS 80 mS 0.003% (15 bits + sign)
 

 Moving Average filter

 

   
Filter setting samples averaged 1 input @ 200 samples/sec 4 inputs @ 50 samples/sec
0 1 5 mS 80 mS
1 2 10 mS 160 mS
2 4 20 mS 320 mS
3 8 40 mS 640 mS
4 16 80 mS 1280 mS

 

Connectors

Type

Power supply 2 pole screw/plug connector
Input 1-4 3 pole screw/plug connector (Gnd, I, U)
Cdios bus 10 pole Flatcable female
10 pole Flatcable male
 
Signaling LEDs Color Text
On each input Red Active
 

General

Conditions

Min. Typ. Max. Units
I/O module Controlled by Cdios controller

-

- - -
Module select via 4 dipswitches - - - -
MPU Motorola 68HC908 - 8 - Mc
MPU watchdog - - 52 - ms
MTBF T amb..=40°C - 87000 - h
Warranty - - 2 - year
 

Environmental

Conditions

Min. Typ. Max. Units
Operating temperature - -20 - 70 °C
Storage temperature - -25 - 80 °C
Relative humidity at 40°C non Cond. - - 90 %
Burn in cycle 25°C .. -25°C .. 60°C - 1 - cycle
 

Physical

Housing 35 mm DIN rail
Dimensions L * W * H 96 * 61 * 55 mm (incl. rail)
Color Light Grey
Protection class IP32
Weight 101 g
 

Conformity

EN 50081-1 Electromagnetic compatibility -Generic emission standard- Residential, commercial and light industry environment
EN 50081-2 Electromagnetic compatibility -Generic emission standard- Industrial environment
EN 50082-1 Electromagnetic compatibility -Generic immunity standard-Residential, commercial and light industry environment
EN 50082-2 Electromagnetic compatibility -Generic immunity standard- Industrial environment
EN 55022 Emits and methods of measurement of radio disturbance characteristics of information technology equipment
EN 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use

 


Home